Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Hand Surgery (British and European Volume)
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by PRING, D. J.
Right arrow Articles by COOMBS, R. R. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by PRING, D. J.
Right arrow Articles by COOMBS, R. R. H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Articles

The Mechanical Properties of Human Flexor Tendons in Relation to Artificial Tendons

D. J. PRING
A. A. AMIS
R. R. H. COOMBS

From the Royal Postgraduate Medical School and the Imperial College of Science and Technology

The continuation of an unacceptable failure rate with tendon repair or grafting procedures, largely due to adhesions, suggested that an artificial flexor tendon could be an attractive alternative. A literature search found no published data of the mechanical properties of fresh human finger flexor tendons, so a study of the strength and extensibility of 153 tendons was carried out. The bone insertion strength of twenty middle finger tendons was also examined. The results showed that an artificial tendon should have a strength of approximately 1500N, and that it should extend 13% at that load, an elongation of 26mm for a tendon 200mm long. The insertion strength was less than a half of the tendon strength. This data will allow an artificial flexor tendon to be designed with sufficient strength and the correct elastic properties to allow its function to integrate reliably with natural tendons in adjacent fingers.

Journal of Hand Surgery (British and European Volume), Vol. 10, No. 3, 331-336 (1985)
DOI: 10.1016/S0266-7681(85)80055-3


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?