Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Hand Surgery (European Volume)
This Article
Right arrow Full Text (OnlineFirst PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Hems, T E J
Right arrow Articles by Rooney, B
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hems, T E J
Right arrow Articles by Rooney, B
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Article

Open reduction and plate fixation of dorsally displaced fractures of the distal radius: surgical technique, clinical and radiological outcome

T E J Hems* and B Rooney

The Victoria Infirmary

* To whom correspondence should be addressed. E-mail: t.e.j.hems{at}doctors.org.uk.


   Abstract

Thirty-five unstable dorsally displaced fractures of the distal radius in 34 patients (mean age 39) were studied; 28 fractures were intra-articular. All fractures had open reduction and fixation, through a dorsal approach, with mini-fragment plates placed between the first and second dorsal tendon compartments and deep to the fourth compartment. A congruous reduction of the articular surface was obtained in all cases. Twenty-four patients were available for follow-up (median 38 months). The Modified Mayo wrist score was excellent in 12 cases, good in four, and fair in eight. The median Patient Evaluation Measure score was 23.5. There were no cases of extensor tendon rupture. Radiographic assessment at follow-up showed a mean palmar angle of 6°. There was evidence of osteoarthritis in six patients who had had intra-articular fractures. Open reduction and plating gives satisfactory medium term results for treatment of displaced intra-articular fractures of the distal radius in young patients.

First published on August 17, 2009
Journal of Hand Surgery (European Volume) 2009, doi:10.1177/1753193409106178


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?