Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Hand Surgery (European Volume)
This Article
Right arrow Full Text (OnlineFirst PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Tägil, M.
Right arrow Articles by Kopylov, P
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tägil, M.
Right arrow Articles by Kopylov, P
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Article

Correlation between range of motion and implant fracture: a 5 year follow-up of 72 joints in 18 patients in a randomized study comparing swanson and avanta/sutter MCP silicone prosthesis

Magnus Tägil, Mr*, M Geijer, P Malcus, and P Kopylov

* To whom correspondence should be addressed. E-mail: magnus.tagil{at}ort.lu.se.


   Abstract

Eighteen out of 18 rheumatoid patients (at one centre of a two-centre 30 patient study previously reported) with a mean age of 56 years, and 72/72 operated joints were randomized to Avanta/Sutter or Swanson MCP prostheses and followed for 5 years. Both ulnar deviation and extension lag were improved already at 6 weeks and remained improved at 5 years. The Avanta prosthesis had a better range of motion (ROM) than the Swanson. Six of nine patients with Avanta/Sutter implants had at least one implant fracture compared to 1/9 patients with the Swanson implant (P = 0.05) but fracture did not change the outcome subjectively. The ROM at 3 months correlated with the occurrence of an implant fracture at 5 years and a greater early ROM may be related to implant fracture. At 5 years patients remained satisfied and the deformities remained corrected.