Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Hand Surgery (European Volume)
This Article
Right arrow Full Text (OnlineFirst PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Jarrett, C. D.
Right arrow Articles by Hutton, W. C.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jarrett, C. D.
Right arrow Articles by Hutton, W. C.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Article

THE 2. 5 MM PUSHLOCK SUTURE ANCHOR SYSTEM VERSUS A TRADITIONAL SUTURE ANCHOR FOR ULNAR COLLATERAL LIGAMENT INJURIES OF THE THUMB: A BIOMECHANICAL STUDY

C. D. Jarrett, G. R. McGillivary, and W. C. Hutton, Dr*

Emory University School of Medicine

* To whom correspondence should be addressed. E-mail: William.Hutton{at}emoryhealthcare.org.


   Abstract

We compared the biomechanical strength of the 2.5 mm PushLock suture anchor with a traditional Bio-SutureTak suture anchor in repair of ulnar collateral ligament injuries. Iatrogenic ulnar collateral ligament injuries in 18 cadaveric thumbs were repaired and used to test for load to failure and cyclic loading. The average force required to generate a 2 mm gap was 7.7 N for the 2.5 mm PushLock and 6.3 N for the Bio-SutureTak (p = 0.04). The ultimate load to failure was 28.0 N for the 2.5 mm PushLock and 18.8 N for the Bio-SutureTak (p = 0.16). There were no statistical differences between the two suture anchors under cyclic loading. The 2.5 mm PushLock suture anchor provides significantly stronger resistance to 2 mm gap formation at the repair site and is less likely to fail at the suture–ligament interface. However, there was no difference in the load to failure between the two suture anchors.