Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Hand Surgery (British and European Volume)
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by SAITOH, S.
Right arrow Articles by NAKATSUCHI, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by SAITOH, S.
Right arrow Articles by NAKATSUCHI, Y.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Articles

Long-Term Results of Vein Grafts Interposed in Arterial Defects Using the Telescoping Anastomotic Technique and Fibrin Glue

S. SAITOH
Y. NAKATSUCHI

From Department of Orthopaedics, Shinshu University School of Medicine, Matsumoto City, Japan

Correspondence: Satoru Saitoh, MD, Department of Orthopaedics, Shinshu University School of Medicine, Asahi 3-1-1, Matsumoto City, 390 Japan.

Fibrin glue has been applied in the anastomosis of vein grafts placed in rat femoral arteries using the telescoping technique at both ends of the graft. 34 out of 35 grafts which were patent 1 to 3 weeks post-operatively were kept for 3 months to assess the long-term patency, and the effect of the glue on the diameters of the graft and femoral artery. All 34 grafts were patent 3 months post-operatively. Excessive enlargement of the graft diameter was alleviated by the fibrin glue without affecting the diameter of the femoral artery. The diameter at the proximal anastomosis was 66% and that at the distal anastomosis was 87% of the diameter of the femoral artery.

Journal of Hand Surgery (British and European Volume), Vol. 21, No. 1, 47-52 (1996)
DOI: 10.1016/S0266-7681(96)80011-8


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?