Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Hand Surgery (British and European Volume)
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by LO, I. K. Y.
Right arrow Articles by CHESS, D. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by LO, I. K. Y.
Right arrow Articles by CHESS, D. C.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Articles

A Biomechanical Analysis of Intrascaphoid Compression Using the Herbert Scaphoid Screw System

An in vitro cadaveric study

I. K. Y. LO
G. J. W. KING
A. D. MILNE
J. A. JOHNSON
D. C. CHESS

From the Musculoskeletal Research Laboratory, Hand and Upper Limb Centre, St Joseph’s Health Centre, London, Ontario, Canada

Correspondence: D. C. Chess MD FRCSC, Hand and Upper Limb Centre, St Joseph’s Health Centre, 268 Grosvenor Street, London, Ontario, Canada N6A 4L6.

The purpose of this study was to evaluate the compressive capabilities of the Herbert scaphoid screw system. A transverse osteotomy was performed at the waist of eight scaphoids removing a 3 mm wafer of bone. A custom-designed load washer was inserted within this defect to measure intrascaphoid compression during Huene guide application, during screw insertion, after screw insertion and after guide release. The intrascaphoid compression was noted to peak during screw insertion; however it dramatically decreased without any clinical subjective evidence of decreased insertional torque by the surgeon. The average final compression as a percentage of maximal compression was 38 (SD 26) %.

Journal of Hand Surgery (British and European Volume), Vol. 23, No. 2, 209-213 (1998)
DOI: 10.1016/S0266-7681(98)80176-9


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?