Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Hand Surgery (British and European Volume)
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by LUNDBORG, G.
Right arrow Articles by LINDBERG, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by LUNDBORG, G.
Right arrow Articles by LINDBERG, S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Articles

Artificial Sensibility Based on the Use of Piezoresistive Sensors

Preliminary observations

G. LUNDBORG
B. ROSÉN
K. LINDSTRÖM
S. LINDBERG

From the Departments of Hand Surgery and Biomedical Engineering, University Hospital, Malmö, and the Department of Electrical Measurement, Lund Institute of Technology, Sweden

Correspondence: Prof. G. Lundborg. Department of Hand Surgery. University Hospital, S–205–02 Malmö, Sweden. E-mail: Goran.Lundborg{at}hand.mas.lu.se

Piezoresistive sensors, applied to the fingertips of non-sensate fingers, were used for the detection of touch and pressure in four patients with recent median nerve repairs, and in one patient using a myoelectric prosthesis. The signals from the sensors, produced by the tactile stimuli, were processed and transposed as electrical stimuli to sensate skin of the ipsi- or contralateral arm by the use of skin electrodes. With this setup the test subjects could rapidly learn to differentiate between tactile stimuli applied to different fingers, thereby regaining spatial, resolution in the hand. All five patients rapidly improved their ability to regulate the power of pinch grip without the help of vision. The patient with a hand prosthesis rapidly learned to discriminate between four different levels of pressure, applied to the thumb by four different Semmes-Weinstein monofilaments (75, 125, 280 and 450 g). These results indicate that the system is of potential value for patients lacking sensibility or using prostheses.

Journal of Hand Surgery (British and European Volume), Vol. 23, No. 5, 620-626 (1998)
DOI: 10.1016/S0266-7681(98)80016-8