Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Hand Surgery (British and European Volume)
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by WILLIAMS, N. W.
Right arrow Articles by HOSE, D. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by WILLIAMS, N. W.
Right arrow Articles by HOSE, D. R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Articles

Computer Model Analysis of the Swanson and Sutter Metacarpophalangeal Joint Implants

N. W. WILLIAMS
J. M. T. PENROSE
D. R. HOSE

From the Department of Plastic Surgery, Northern General Hospital and the Department of Medical Physics and Clinical Engineering, Royal Hallamshire Hospital, Sheffield, UK

Correspondence: Mr N. W. Williams, Department of Plastic Surgery, Northern General Hospital, Herries Road, Sheffield S5 7AU, UK. E-mail: Cybermanus{at}aol.com

A representative model which mimics the behaviour of Silastic® finger metacarpophalangeal joint implants was constructed using a finite element software package. The modelled implants were moved through a range of flexion, lateral deviation and a combination of both. Pistoning of both implants stems occurred within the modelled medullary cavities. For equivalent flexion angles, the Sutter implant produced a higher stress field than the Swanson implant, and the field was positioned at the central hinge mechanism. In both implants, lateral deviation increased the internal stress concentrations more than when pure flexion was applied. Overall the Swanson style of implant had lower stress magnitudes than the Sutter implant, and it is predicted that the Sutter implant will be more likely to fail than the Swanson. The failure mode for the Sutter implant would be at the central hinge region. The Swanson implant is likely to fail at the central hinge-stem interface regions.

Journal of Hand Surgery (British and European Volume), Vol. 25, No. 2, 212-220 (2000)
DOI: 10.1054/jhsb.1999.0352


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?