| Sign In to gain access to subscriptions and/or personal tools. |
Ultrasound for Diagnosis of Scaphoid FracturesFrom the Department of Orthopaedic Surgery and the Department of Radiology, Aarhus Amtssygehus, University Hospital of Aarhus, Denmark Correspondence: Dr Bo Munk, Vestre Strandalle 77, DK8240 Riskov, Denmark. E-mail: dr.munk{at}dadlnet.dk We investigated the diagnostic value of two different ultrasound scanning methods for the early diagnosis of acute scaphoid fractures. Fifty-seven patients with ten scaphoid fractures were assessed within a week of injury. The accuracy of the ultrasound assessment was 84% and its specificity was 91%. However, its sensitivity was only 50%. We conclude that ultrasound examination is unreliable for the diagnosis of acute scaphoid fractures.
Journal of Hand Surgery (British and European Volume), Vol. 25, No. 4,
369-371 (2000) |
||||