Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Hand Surgery (European Volume)
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
1753193408097860v1
34/2/215    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by FRANSSEN, B. B. G. M.
Right arrow Articles by KON, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by FRANSSEN, B. B. G. M.
Right arrow Articles by KON, M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Articles

Hammering Versus Drilling of Sharp and Obtuse Trocar-Point K-Wires

B. B. G. M. FRANSSEN
A. H. SCHUURMAN
A. B. MINK VAN DER MOLEN
M. KON

From the Department of Plastic Reconstructive and Hand Surgery, University Medical Centre Utrecht, The Netherlands

Correspondence: B. B. G. M. Franssen, Department of Plastic Reconstructive and Hand Surgery University Medical Centre Utrecht, Room number G.04.122, PO Box 85500, 3508 GA Utrecht, The Netherlands. Tel.: +31-88-7556897; fax: +31-30-2516097. E-mail:bbgmfranssen{at}gmail.com.

Kirschner wire characteristics affect the heating of bone during insertion and the subsequent strength of fixation. We inserted 90 sharp and 90 obtuse trocar-tip K-wires into 90 fresh frozen human cadaver metacarpals using either a drill or a pneumatic hammer. The temperature elevation, insertion time and extraction force were measured for four K-wire insertion combinations: drilling sharp; drilling obtuse; hammering sharp; hammering obtuse. Hammering resulted in significantly lower temperature elevations than drilling. Hammering sharp K-wires resulted in the highest extraction forces. The first and fifth metacarpals showed significantly lower temperature elevations than the other metacarpals, while the insertion time was significantly higher in the second and third metacarpal than in the other metacarpals. Hammering sharp trocar-tip K-wires minimises thermal damage to bone and gives the strongest fixation.

Key Words: K-wire tip • pneumatic hammer • drill • metacarpal • temperature • extraction force

This version was published on April 1, 2009

Journal of Hand Surgery (European Volume), Vol. 34, No. 2, 215-218 (2009)
DOI: 10.1177/1753193408097860


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?