Journal of Hand Surgery (European Volume)

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Register here to gain access to SAGE's 500+ Journals Online

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Abstract Freely available
Right arrow Free Full Text (Free PDF) Free
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by WIGDEROWITZ, C. A.
Right arrow Articles by ABBOUD, R. J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by WIGDEROWITZ, C. A.
Right arrow Articles by ABBOUD, R. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Journal of Hand Surgery (European Volume), Vol. 32, No. 6, 700-704 (2007)
DOI: 10.1016/J.JHSE.2007.06.019


Articles

Adapting the Fastrak® System for Three-Dimensional Measurement of the Motion of the Wrist

C. A. WIGDEROWITZ, I. SCOTT, A. JARIWALA, G. P. ARNOLD and R. J. ABBOUD

From the Department of Orthopaedics and Trauma Surgery, TORT Centre, Ninewells Hospital, Dundee, Scotland and the Institute of Motion Analysis and Research (IMAR), TORT Centre, Ninewells Hospital, Dundee, Scotland

Correspondence: Mr C. A. Wigderowitz, Senior Lecturer, Department of Orthopaedics and Trauma Surgery, TORT Centre, Ninewells Hospital, Dundee DD1 9SY, Scotland. Tel.: +13 82 425746; fax: +13 82 496200. E-mail:cawigderowitz{at}lineone.net


    Abstract
 TOP
 Abstract
 MATERIAL AND METHODS
 RESULTS
 DISCUSSION
 References
 
The Polhemus Fastrak® short-range miniature transmitter and mini-receivers allow wrist motion to be measured continually in three dimensions, registering patterns of motion, which until now were difficult to quantify. The current study aimed to determine the applicability and repeatability of the Fastrak® system when assessing wrist movements during a set protocol of activities. The device was found to be easy to use and repeatable; the Fastrak® system showed a mean error of up to 3° in all movements tested. Its assessment of range of motion correlated with the results in the literature. The Fastrakv® system was suitable for continuous registration of movements during the performance of set tasks in either of the wrists. It has the potential to be used for documentation of wrist motion in clinics for various pathologies and for assessing outcomes in wrist surgeries.

Key Words: the Fastrak® system • continuous wrist motion • three-dimensional assessment • electromagnetic goniometer • normal wrist motion • functional tasks

Dynamic studies of wrist motion and accurate assessment of specific wrist angles during various movements are difficult using simple goniometers, which are limited to measurements in a single plane with poor inter-observer reproducibility. Biaxial goniometers have the added problems of inherent cross-talk and zero-drift errors as a result of forearm rotations (Buchholz and Wellman, 1997). Studies with computed tomography and magnetic resonance are fraught with problems of resource management. Objective scoring systems require validation and are prone to inconsistencies (Bradway et al., 1989).

The Polhemus electromagnetic systems (Isotrak® and Fastrak®) have both been used to measure the spatial positioning and three-dimensional movements of the ankle and the subtalar joints continuously, with low variability and with an error of up to 1° (Rendall and Abboud, 1999). The continuous registration of three-dimensional data enables the registration and analysis of patterns of movements, thus expanding our understanding of joint functions, both in normal subjects and in specific pathologies. A recent development of this system has allowed further miniaturisation of the transmitter and sensors, enabling its use on small joints such as those of the wrist and hand (Leonard et al., 2005).

Before adopting the Fastrak® system for any particular clinical use, it is necessary to assess its suitability. The current study examines the application of the Fastrak® system in the measurement of wrist function. Initially, a device was developed to adjust the Fastrak® system to the wrist and the hand consistently. A protocol of activities was then used to standardise a number of movements performed in activities of daily living. Finally, the Fastrak® system was attached to both wrists sequentially to assess the suitability and repeatability of the system.


    MATERIAL AND METHODS
 TOP
 Abstract
 MATERIAL AND METHODS
 RESULTS
 DISCUSSION
 References
 
A group of 27 young healthy volunteers was recruited. The subjects were excluded if they had any history of previous wrist trauma, joint disease or suffered from any other condition affecting movement of the upper limbs. Ethical approval was granted for the study by the local research ethics committee.

The Fastrak® system consists of one transmitter and up to four sensors. The transmitter produces an electromagnetic field and determines the three-dimensional position and orientation of the sensors when they are moved within that field. The electromagnetic field range of the miniaturised system is approximately 30 cm3; making it ideal for use on the wrist. We used one sensor for measuring wrist motion for optimum frequency recording (120 Hz). However, up to four sensors can be studied simultaneously by the transmitter at lower frequencies (Polhemus, 2000).

The transmitter was mounted on the dorsum of the forearm, 3 cm proximal to Listers’ tubercle, and held in place with an elastic strap. This location was chosen as it is not affected by movement of the skin folds at the wrist during extension and also has limited soft tissue bulk, thereby minimising motion artefact. The sensor was attached to the dorsum of the hand, superficial to the head of the third metacarpal, so providing adequate distance from the transmitter and, thereby, amplifying small variations in movements. In addition, this position is easy to locate and standardise. Finally, as there is very little or no movement in the carpometacarpal joints, the movements at the head of third metacarpal reflect the movements of the wrist. The sensor was attached to the hand with double-sided adhesive tape. The subject’s forearm rested in a custom-built wooden rig, which provided support without restricting the wrist movements. We selected wood as the material for the rig as it does not interfere with the electromagnetic field of the transmitter (Fig 1).


Figure 10320700
View larger version (99K):
[in this window]
[in a new window]

 
Fig 1 Illustration of transmitter secured to the forearm by a blue Velcro strap and the sensor mounted on the third metacarpal.

 
The Fastrak® system was then calibrated in the neutral position in the flexion–extension and the radial–ulnar planes. To do this, the hand was placed in the anatomical position with the axis of the hand coinciding with the long axis of the forearm, which was denoted as the neutral position. This became the reference point from which further movements in the wrists were measured.

The protocol developed for our study consisted of three tasks. The first task (Task 1) measured uni-planar movements of the wrist. The subjects were asked to perform full flexion and extension of the wrist (sagittal motion) and full radial and ulnar deviation (coronal motion). Task 2 involved picking up an object and moving it from the radial to the ulnar side across a 5 cm high barrier and placing it on the other side of the barrier and 10 cm away from it (Fig 2). In the third task (Task 3), the subject was asked to make parallel longitudinal pen marks approximately 5 cm in length moving from the radial to the ulnar side across the board on which the hand was resting and drawing a total of three lines. The latter two tasks investigated wrist motion while performing functional tasks which had been used previously in studies of wrist motion and were noted to be easily understood and simple to perform (Smeulders et al., 2001).


Figure 20320700
View larger version (101K):
[in this window]
[in a new window]

 
Fig 2 Illustration of the subject performing the lift and move-task (Task 2) with a plastic cap.

 
The sequences of tasks were explained and demonstrated to the subjects who were then allowed a short period of training before data collection. Once the task had been learnt, it was performed sequentially with the right and the left hands. After erasing all the marks, the transmitter was remounted on the right wrist and the same task was performed again in what was referred to as ‘Run 2’. This was done to study repeatability.

The comparison between the left and the right wrists was used to investigate the suitability of the system for measurement of movements in either of the two wrists. The range of motion in the relevant planes was extracted from the raw data for analysis.

Statistical analyses using general linear models and paired t-tests were performed on the data.


    RESULTS
 TOP
 Abstract
 MATERIAL AND METHODS
 RESULTS
 DISCUSSION
 References
 
The Fastrak® system was found to be easily adaptable to the wrist with no substantial discomfort being reported by any of the subjects. No side effects or injuries were noted following its repeated use.

Twenty-seven healthy young volunteers underwent the described measurements. The mean age of this group was 23 (range 18–30) years. There were 15 women and 12 men. Nine were left-handed and 18 were right-handed.

The Fastrak® system acquired the three-dimensional data continuously during performance of the various movement tasks carried out. Fig. 3 illustrates a typical pattern of motion recorded at the wrist during the performance of Task 1 and shows the interlinking of various uni-planar movements of wrist, viz extension, flexion, radial and ulnar deviation. As expected, the maximum movement was noted in the flexion–extension plane. Radial deviation occurred with maximum extension while ulnar deviation occurred with maximal flexion. The description of movements is limited to those in the flexion–extension plane and in radial–ulnar deviation. The movements in the axial plane were not considered, as they were of very small magnitude with these set tasks and pronation–supination movements occur primarily at the proximal and distal radioulnar joints, which were not studied.


Figure 30320700
View larger version (17K):
[in this window]
[in a new window]

 
Fig 3 Three-dimensional motion recording by the Fastrak® system for Task 1.

 
Studying the total arc in the flexion–extension plane, there is little difference between the right and the left wrists (Table 1). It was noted that there was greater flexion of the left wrists as compared to the right wrists. This difference was also identified in the lift and move task (Task 2).


View this table:
[in this window]
[in a new window]

 
Table 1 Comparing the left and the right wrists during Task 1

 
The results of movements in the radial–ulnar deviation are demonstrated in Table 1. There was no statistically significant difference between the movements occurring in the right and left wrists in radial–ulnar deviation. Also, no significant differences were found when the effect of dominance was taken into account.

Table 2 records the movements noted in the lift and move task (Task 2). Negative figures indicate flexion and ulnar deviation. For this task, most subjects used three quarters of the total radioulnar movement possible, but only one-third of the total flexion and extension movement possible.


View this table:
[in this window]
[in a new window]

 
Table 2 Demonstrating the ranges of motion for the lift and move task (Task 2)

 
The results for the writing simulation task (Task 3) showed considerable variability between subjects and between the two wrists of the same individual (Table 3). The total range of movement required to perform this task was relatively small when compared to the total movement possible at the wrist. Again, as above, negative figures indicate flexion and ulnar deviation. There was no statistically significant difference in the mean values of either Task 2 or 3 between the left and the right wrists.


View this table:
[in this window]
[in a new window]

 
Table 3 Demonstrating the ranges of motion for the writing task (Task 3)

 
The standard deviation for the movements for all the patients, including ‘Run 2’ was calculated. The standard error of the series of movements in Task 1 is depicted in Table 4. The Fastrak® system revealed a mean variation of up to 3° while comparing the measurements in Task 1 on the right wrist and in ‘Run 2’ (Table 5).


View this table:
[in this window]
[in a new window]

 
Table 4 Demonstrating the standard error of the mean for various measurements during Task 1

 

View this table:
[in this window]
[in a new window]

 
Table 5 Demonstrating the repeatability of the system by comparing the two runs

 

    DISCUSSION
 TOP
 Abstract
 MATERIAL AND METHODS
 RESULTS
 DISCUSSION
 References
 
The Fastrak® system successfully registered the continuous three-dimensional movements of the wrist throughout a wide range of wrist motion. It allowed these measurements to be taken while the subject performed various simple tasks that were devised to mimic common everyday activities. Intraobserver measurements were found to be repeatable, with low error value compared to that reported in the literature for comparable methods (Jonsson and Johnson, 2001; Small et al., 1996; Urban et al., 2002). These findings correlate well with those of Rendall and Abboud (1999) who found the Isotrak® system, which is a previous, bulkier version of the Fastrak®, to be suitable for assessing ankle and subtalar joint motion. The Fastrak® system is also ‘user friendly’: the transmitter and the sensor were easy to attach and calibrate for repeated use, the set-up protocol was simple and subjects did not have difficulties performing the tasks after the initial demonstration.

This suggests that this instrument may also be used for patients with diseases of the wrist or following interventions for treatment, although such possibilities were not investigated in this study. The present work is limited by the small number of tasks investigated, but new ones could, probably be developed to look into the requirements of specific groups of patients or volunteers such as musicians and other artists. People in different age groups and with specific pathologies may also need specific protocols. The concept of continuous, three-dimensional measurements will allow not only the measurement of the range of movement, but also analysis of different patterns of function.

The literature shows that there is a large individual variability in the range of movements of the wrist (Boone and Azen, 1979; Brumfield and Champoux, 1984; Gunal et al., 1996; Palmer et al., 1985). The flexion–extension arc of movement in this study was found to be less than that reported by Stuchin (1989) and Sarrafian et al. (1977). Conversely, the radial–ulnar deviation arc was greater than that reported by Youm et al. (1978) and Volz et al. (1980). These discrepancies may simply reflect variability in the normal population. Our volunteers belonged to a specific group with a small age range, which was different from the other study samples quoted above.

The Fastrak® system demonstrated that most subjects used extension of the wrist while varying from radial to ulnar deviation during the writing-simulating test. It suggests that limitation of these positions may seriously impair ability to write, whilst limitation of flexion and radial deviation are less likely to be relevant. This agrees with previous work on normal wrist movement and function (Brumfield and Champoux, 1984).

Substantial developments in equipment and protocols are still necessary. The concept of dynamic three-dimensional measurements in the wrist is a considerable advance relative to our current static range of movement measurements. The current work largely confirms what is already well-established knowledge regarding patterns of wrist motion. However, additional groups of patients and volunteers with a variety of pathologies and following specific surgical interventions may be studied in the future while performing specific and relevant tasks. Such studies may lead to better understanding of the biomechanics of the hand during different tasks and activities and how it is altered by specific pathological conditions.

Received for publication February 7, 2006. Accepted for publication June 19, 2007.


    References
 TOP
 Abstract
 MATERIAL AND METHODS
 RESULTS
 DISCUSSION
 References
 

  • Boone DC, Azen P (1979). Normal range of motion of joints in male subjects. Journal of Bone and Joint Surgery, 61A: 756–759.
  • Bradway JK, Amadio PC, Cooney WP (1989). Open reduction and internal fixation of displaced, comminuted intra-articular fractures of the distal end of the radius. Journal of Bone and Joint Surgery, 71A: 839–847.
  • Brumfield RH, Champoux JA (1984). A biomechanical study of normal functional wrist motion. Clinical Orthopaedics and Related Research, 187: 23–25.[Medline] [Order article via Infotrieve]
  • Buchholz B, Wellman H (1997). Practical operation of a biaxial goniometer at the wrist joint. Human Factors, 39: 119–129.[CrossRef][ISI][Medline] [Order article via Infotrieve]
  • Gunal I, Kose N, Erdogan O, Gokturk E, Seber S (1996). Normal range of motion of the joints of upper extremity in male subjects, with special reference to side. Journal of Bone and Joint Surgery, 78A: 1401–1404.
  • Jonsson P, Johnson PW (2001). Comparison of measurement accuracy between two types of wrist goniometer systems. Applied Ergonomics, 32: 599–607.[CrossRef][ISI][Medline] [Order article via Infotrieve]
  • Leonard L, Sirkett D, Mullineux G, Giddins GEB, Miles AW (2005). Development of an in vivo method of wrist joint motion analysis. Clinical Biomechanics, 20: 166–171.[CrossRef][Medline] [Order article via Infotrieve]
  • Palmer AK, Werner FW, Murphy D, Glisson R (1985). Functional wrist motion: a biomechanical study. Journal of Hand Surgery, 10A: 39–46.[Medline] [Order article via Infotrieve]
  • Polhemus (2000). Fastrak® User’s Manual Supplied with the System.
  • Rendall GC, Abboud RJ (1999). The development of a three plane system for the measurement of the ankle/subtalar joint complex in gait. The Foot, 9: 31–39.[CrossRef]
  • Sarrafian SK, Melamed JL, Goshgarian GM (1977). Study of wrist motion in flexion and extension. Clinical Orthopaedics and Related Research, 126: 153–159.[Medline] [Order article via Infotrieve]
  • Small CF, Bryant JT, Dwosh IL, Griffiths PM, Pichora DR, Zee B (1996). Validation of a 3D optoelectronic motion analysis system for the wrist joint. Clinical Biomechanics, 11: 481–483.[CrossRef][Medline] [Order article via Infotrieve]
  • Smeulders M, Kreulen M, Bos KE (2001). Fine motor assessment in chronic wrist pain: the role of adapted motor control. Clinical Rehabilitation, 15: 133–141.[Abstract/Free Full Text]
  • Stuchin S. Biomechanics of the wrist. In: Nordin M, Frankel V (Eds). Basic biomechanics of the musculoskeletal system. 2nd Edn., LEA and Febiger, 1989: 261–274.
  • Urban V, Kalberer F, Roos M, Dumont CE (2002). Reliability of active range-of-motion measurement of the rotation in the forearm: comparison of three measurement devices. Zeitschrift fur Orthopadie und ihre Grenzgebiete, 140: 72–76.[CrossRef][ISI][Medline] [Order article via Infotrieve]
  • Volz RG, Lieb M, Benjamin J (1980). Biomechanics of the wrist. Clinical Orthopaedics and Related Research, 149: 112–117.[Medline] [Order article via Infotrieve]
  • Youm Y, McMurthy RY, Flatt AE, Gillespie TE (1978). Kinematics of the wrist. I: an experimental study of radial–ulnar deviation and flexion–extension. Journal of Bone and Joint Surgery, 60A: 423–431.

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?



This Article
Right arrow Abstract Freely available
Right arrow Free Full Text (Free PDF) Free
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by WIGDEROWITZ, C. A.
Right arrow Articles by ABBOUD, R. J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by WIGDEROWITZ, C. A.
Right arrow Articles by ABBOUD, R. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?